Common malfunction/Countermeasure of spinning metering pump
                     
	One problem: silk fineness unevenness
	Reasons and Countermeasures:
	Abnormal: check the operation of the metering pump, check the metering pump.
	Component leakage: fastening bolts or replacing components.
	The speed of the metering pump is unstable: the speed of the metering pump is adjusted..
	Insufficient pump pressure before: increase the pressure of the pump.
	Filament or filament breaking: according to the relevant treatment measures.
	Question two: metering pump leakage
	Reasons and Countermeasures:
	The pressure of the pump is too large: the replacement of the components.
	Pump seat uneven or there are residues: clean residue, check the replacement pump seat.
	Fixed screw loosening: screw according to correct method.
	Question three: metering pump card or broken shaft
	Reasons and Countermeasures:
	There are foreign objects in the melt: the material is checked, and the drive shaft should rotate smoothly..
	Pump body preheating is not enough: increase the preheating temperature, prolong the preheating time.
	Not timely shipment, dry grinding time is too long: after the boot material.
	Boot speed time is too fast: the appropriate extension of speed time.
	The transmission shaft is not concentric: adjust the transmission shaft and the coaxial degree of the metering pump.